TALK
BACK
BACK
Cargo Operations

Loading Rate
Q:
What are the limitations for the flow rate of static accumulator cargo in a non-inerted cargo tank and why?
A:
- Limit the cargo flow rate to 1 m/s or less at each non-inerted tank inlet until the inlet & bottom structure are submerged by at least twice the filling pipe diameter. This minimises splashing & turbulence, reducing static electricity discharge & the risk of ignition.
- Calculate the 1 m/s limit at the smallest cross-sectional area before the tank inlet, including valves & other restrictions, to ensure the actual inlet velocity does not exceed the limit.
- Ensure the permitted flow rate is clearly communicated to everyone involved in cargo operations. If higher loading rates are required, open additional tank inlets rather than exceeding 1 m/s at any single inlet.
Increase flow rate✓
Increase flow rate×
Ref: ISGOTT 12.1.7.3 / 3.2.1www.safe-lanes.comSL/2026/TB-039
Related services: cargo operations audits.
Related reading: Talkback safety bulletins.