TALK
BACK

Navigational Safety

Q:
Ref SOLAS V/19.6: How are Integrated Bridge / Navigation Systems arranged to inform Bridge Team immediately of the failures?
A:

A) Category 'B' ALARM: If system function is lost.

B) Category 'B' WARNING: In case of a sensor or source failure, loss of communication within the system.

If unacknowledged, warning would change to alarm priority, for the individual sensor or source after 60 seconds, unless otherwise set by the user.

Ref IACS Rec. 95 A 6.7 Test Program, Bridge team must be aware of these settings & onboard functional testing of alerts.
▲ Alarm

➤ High priority of Alert
• Condition requiring immediate attention and action by the bridge team

✓ Warning

➤ Precautionary Alert
• Condition requiring immediate attention but no immediate action, may become hazardous if no action is taken

! Caution

➤ Lowest priority of Alert
• No alarm or warning but still requires attention

Category A • For decision support, graphical information at the task station generating the alert is necessary
Category B • No additional information for decision support is necessary
www.safe-lanes.com
SL/2021/TB-008

Related services: in-port navigation assessment.

Related reading: Talkback safety bulletins.